Offline ups dealers or uninterruptible power source (UPS) is an electrical apparatus that provides emergency power to a load when the input power source or mains power fails. Costa Power Industries Pvt. Ltd. is trustworthy leader in offline ups dealers in Mumbai (UPS) is a device that allows a computer to keep running for at least a short time when the primary power source is lost. Emerson offline ups and APC offline ups devices also provide protection from power surges 600VA to 2000VA. A offline UPS in India contains a battery that "kicks in" when the device senses a loss of power from the primary source . Costa Power is renowned offline ups dealers in Mumbai for any required battery backup for industrial & commercial requirement.
Costa suggests & deals in varied types of offline UPS and their attributes often cause confusion in the data center industry. Costa believes as offline ups dealers in India & it is widely believed that there are only two types of UPS battery systems, namely offline UPS suppliers in Mumbai and online UPS. And we supply both standby ups in Mumbai & online ups suppliers in India with all capacity.
CPIPL is ups suppliers for standby office offline UPS which runs the computer off of the normal utility power until it detects a problem.... A power inverter simply turns the DC power delivered by the battery into 120-volt, 60-Hertz AC power. In a continuous offline UPS, the computer is always running off of ups battery power and the battery is continuously being recharged.
Online ups systems term refers to the condition when converter is in operation when power in the line is present. office offline ups mode refers to a condition when converter operation start after the main line is off or not available. Therefore, online UPS is a stage which is introduced between the load and mains. And we proudly introduce ourselves as online ups suppliers, offline ups dealers, online ups dealers as well in all parts of India with all rating.
An online UPS system in India, online ups 3kva price comprises four main parts : A rectifier / charger block, a UPS battery, an inverter and a static switch. The online UPS has an internal static bypass circuit that is the first line of defense should you experience a failure within your UPS system. The rectifier has two main functions the battery is the heart of your UPS battery system. CPIPL is leader as offline ups dealers & offline ups suppliers, offline ups distributors and offline ups manufacturers with all parts.
The offline UPS is more efficient as compared to the inverter. The offline UPS manufacturers provides the electric backup to the appliances without delay and fluctuation. And, the inverter is a medium between the primary power supply and the offline ups battery. CPIPL take honor as ups leading offline ups suppliers in Mumbai as well offline ups manufacturers in Mumbai.
Offline UPS Bypass mode is when you switch the circuit from going through the offline UPS to going around or bypassing it. A manual bypass switch is used to remove the Offline UPS system from the circuit for servicing or maintenance or if it is no longer working correctly. Best to leave it on so the offline ups keeps a float charge. If you do insist on turning it off at least make sure it stays on for several hours every now and then to keep the battery topped up. Lot of electronics don't like on/off cycles, though a offline ups is simple enough I don't think it would care too much.
Costa Power Industries Pvt Ltd offers to understand end user point of view that kVA is a unit of apparent power, which is electrical power unit. 1 kilo-volt-ampere is equal to 1000 volt-ampere: 1kVA = 1000VA. 1 kilo-volt-ampere is equal to 1000 times 1 volt times 1 ampere : 1kVA = 1000.1V.1A.
Batteries can store only Direct Current (DC) power. AC power cannot be stored unless converted to DC (which is done by using transformer and recifier + filter circuitry). There are primarily two modes of operation of the UPS i.e. Mains mode and Inverter mode. CPIPL offers special rates for offline ups in each make of Emerson offline ups along with APC offline ups & BPE offline ups in Domestic level as well export Globally.
MODEL | SPECIFICATION | EXi 600 VA | LXi 600 VA | CX 600 VA | 1000 VA LB |
---|---|---|---|---|---|
CAPACITY | VA/W | 600 VA/360 Watt. | 600 VA/360 Watt. | 600 VA/360 Watt. | 1000 VA/600 Watt. |
Input | Voltage | 220/230 VAC | |||
Voltage Range | 140-300 VAC | ||||
Frequency Range | 50 Hz | ||||
OUTPUT | AC Voltage Regulation (Batt. Mode) | ±10% | |||
Frequency Range (Batt. Mode) | 50 Hz ±1 Hz | ||||
Transfer Time | Typical 2-6 ms | ||||
Waveform (Batt. Mode) | Simulated Sine Wave | ||||
Overload | 110% +/-10% Shutdown after 5 mins | ||||
BATTERY | Battery Type & Number | 12 V/9Ah x 1 | 12 V/7 Ah x 2 | 12 V/7 Ah x 1 | 12VDC |
Floating Charge Voltage | 13.7 VDC ± 2% | ||||
Overcharge Protection | 14.5VDC ± 2% | ||||
Maximum Charge Current | 20 A | ||||
Typical Recharge Time | 6-8 hours up to 90% capacity | ||||
TRANSFER TIME | Minimum line break for transfer to battery | Typical 4-8 msec | |||
PHYSICAL | Dimension, D X W X H (mm) | 282 x 101 x 142 | 353 X 150 x 162 | 279 X 101 X142 | 350 x 146 x 160 |
Model | BR1000G-IN | BR1500G-IN |
---|---|---|
VA | 1000 VA | 1500 VA |
Maximum Load | 600 W | |
Nominal Input Voltage | 220 Vac-240 Vac | |
Online Input Voltage Range | 170 Vac-294 Vac | |
Automatic Voltage Regulation | 182 Vac-216 Vac + 17% and 252 Vac-282 Vac - 17% | |
Frequency Range | 50/60 Hz+ 1 Hz | |
On-battery wave shape | Step-approximated sine-wave | |
Typical Recharge Time | 10 ms, maximum | |
Transfer Time | 10 ms, maximum | |
Operating Temperature | 00 to 400 C (320 to 1040 F ) | |
Storage Temperature | -50 to 450 C (230 to 1130 F ) | |
Unit Dimensions | 30.1 x 11.2 x 38.2 cm (11.9 x 4.4 x 15 in) | |
Unit Weight | 12 kg (26 lbs) | |
Interface | Serial, USB |