Costa Power Industries Pvt. Ltd. is a having global exposure as APC industrial ups Manufacturers in Mumbai, APC industrial ups Suppliers, APC industrial ups Distributors in India and APC industrial ups dealers in Mumbai, APC industrial ups battey systems. Costa Power Industries Pvt. Ltd. had started its operation in the field Since years successfully offering turnkey project services in the field of Electrical, Automation, Instrumentation, Energy Saving and Control with qualified & experience working team with solid technical background. As headquarter is in economic capital of India, located in Mumbai and branches at PAN India.
Costa power provides apc ups battery backup systems with customized ups battery solutions and nationwide with a strong presence in the thane, Mumbai, Mumbai Suburbs, Maharashtra interior parts and in India. Costa Power builds name and get reputation in India as ups industrial suppliers , APC industrial ups dealers in Mumbai chain of APC industrial ups manufacturers in Mumbai , APC industrial online ups dealers in mumbai of global distributors such as APC industrial ups , APC industrial smart online ups , industrial digital online ups , APC industrial modular ups manufacturers , APC industrial online three phase ups , APC industrial online ups in Mumbai etc.
Model | 10-30 kVA 3:3 or 3:1- Phase Industrial UPS | |
---|---|---|
Range | 10 kVA to 30 kVA | |
Phase | Three-phase (3-phase, 380V/400V/415V AC) | |
Display | LCD/LED Display Panel | |
Input | 380V/400V/415V AC | |
Control | Microprocessor-controlled operation for precision power management | |
Redundancy | N+1 Redundancy | |
Monitoring | SNMP-based real-time network monitoring |
Model | E3SUPS40KH | |
---|---|---|
Range | 40 kVA / 40 kW | |
Phase | 3-phase | |
Display | LCD/LED Display Panel | |
Input | 400V (range: 304V to 477V) | |
Control | Microprocessor-controlled operation for precision power management | |
Redundancy | N+1 Redundancy | |
Monitoring | SNMP-based real-time network monitoring |
A 3:3 phase UPS (Three-Phase Input, Three-Phase Output) in the 10-30 kVA range is designed for industrial and commercial applications that require uninterrupted, high-quality power. These UPS systems protect mission-critical equipment from power fluctuations, outages, and electrical disturbances.
A 3:3 UPS takes three-phase power as input and delivers a three-phase output, ensuring efficient and stable power distribution for heavy-duty industrial applications. It is commonly used in:
✅ Manufacturing plants
✅ Data centers
✅ IT infrastructure
✅ Medical equipment
✅ Large office buildings
✅ Industrial automation
These UPS systems use Online Double-Conversion Technology, which provides pure sine wave output and isolates sensitive equipment from voltage fluctuations, surges, and harmonics.
✔ Online Double-Conversion Technology – Ensures a stable and clean power supply
✔ High Efficiency (~95%) – Reduces power consumption and operating costs
✔ Scalability & Redundancy – Can be paralleled for increased capacity
✔ Advanced IGBT-Based Rectifier – Reduces input harmonic distortion (THDi)
✔ Wide Input Voltage Range – Operates efficiently even in fluctuating power conditions
✔ High Power Factor (≥ 0.9 - 1.0) – Ensures optimal power utilization
✔ Generator Compatible – Works smoothly with backup generators
✔ Battery Backup (VRLA or Lithium-Ion) – Configurable based on application needs
✔ Multiple Communication Interfaces – SNMP, RS232, RS485, Modbus for remote monitoring
✔ LCD Display Panel – Provides real-time system diagnostics and alerts
Technical Specifications (Typical 10-30 kVA 3:3 or 3:1 Phase UPS)
Parameter | Specifications | |
---|---|---|
Capacity | 10 kVA, 15 kVA, 20 kVA, 25 kVA, 30 kVA | |
Technology | Online Double-Conversion | |
Input Voltage | 3-phase, 380V/400V/415V AC | |
Output Voltage | 3-phase, 380V/400V/415V AC | |
Input Frequency | 50/60 Hz (Auto-sensing) | |
Output Frequency | 50/60 Hz ± 0.1% | |
Power Factor | ≥ 0.9 - 1.0 | |
Efficiency | 94-96% (online mode) | |
THD (Harmonic Distortion) | ≤3% for linear load | |
Overload Capacity | 125% for 10 min, 150% for 1 min | |
Battery Type | VRLA / Lithium-Ion / Tubular Battery | |
Battery Backup | Configurable (5 min to several hours) | |
Cooling System | Forced air cooling with fans | |
Communication | RS232, RS485, SNMP, Modbus | |
Protection | Overload, Short Circuit, Surge, Overtemperature | |
Operating Temp. | 0°C to 40°C |
For detailed technical information, you can download the product documentation here.Incorporating this UPS into your infrastructure ensures robust protection against power anomalies, safeguarding your critical equipment and data.