Costa Powers offers critical infrastructure technologies and rapidly-deployable customized Emerson ups battery solutions to meet specific business requirements and needs, as Emerson ups dealers, Emerson ups suppliers in India, Emerson industrial ups dealers, Emerson online ups suppliers, Emerson modular ups suppliers, Emerson ups manufacturers in Mumbai, Emerson ups battery systems that sustain your business operations can't go down. Costa Power supports you in improving your ups battery uptime with a full range of innovative Liebert uninterruptible power supplies (UPS) and future-proof, integrated UPS battery systems, that will cover the backup power needs of your IT infrastructure, from small computer rooms at the network edge to enterprise and hyperscale data centers. Discover the best uninterruptible power supplies to protect your application. Vertiv acquired the Emerson Network Power business from Emerson Electric.
Costa Power’s primary customers are businesses across three main end markets data centers, communication networks and commercial & industrial environments. Its principal offerings include:
Costa Power holds immense experience in this domain and is involved in offering wide assortment of UPS System. Costa have reputation for proper customised ups battery backup solution in specific requirements. Costa Power is associated with Vertiv as UPS suppliers for leading Vertiv ups Manufacturers of emerson 1kva online ups, emerson 3kva online ups, emerson 6kva online ups, emerson 10kva online ups and used ups from Mumbai. Emerson Liebert GXT MT Plus CX 3KVA is a true online UPS, which is designed to offer efficient, compact and reliable ups battery solution to modern electronic appliances. It features true double conversion online backup power solution for small data centre, voice networks, data networks and process automation. It offers protection from blackouts, noise interference and brown outs.
A most compact Vertiv UPS developed for harshest power conditions. Liebert ITA provides high density, true double conversion online power protection for servers, voice-data networks and light industrial applications. Capable of delivering loads from Emerson 6kVA ups to Emerson 40kVA ups in a rack-tower convertible form, liebert ITA is available from 2U to 4U. Liebert ITA series provides customers with a reliable source of uninterrupted power supply even in demanding power environments, including very wide input voltage window, extremely tight output voltage regulation, frequency regulation, internal bypass, and input power factor correction.
Costa Power Industries Pvt. Ltd. is a having global exposure as Emerson ups Manufacturers in Mumbai, Emerson ups Suppliers in India, Emerson ups Distributors in Mumbai and Emerson online ups dealers in Pune of Emerson ups battery systems , uninterruptible power supplies , ups power suppliers in mumbai , Emerson ups suppliers in mumbai , Emerson ups dealers , Emerson ups dealers in Mumbai . As headquarter is in economic capital of India, located in Mumbai and branches at PAN India. Costa Power Industries Pvt. Ltd. had started its operation in the field Since year successfully offering turnkey project services in the field of Electrical, Automation, Instrumentation, Energy Saving and Control with qualified & experience working team with solid technical background.
Pioneers in the industry, we offer line interactive ups systems, Emerson line interactive ups, Emerson ups battery systems, 3 kva online ups, industrial ups systems and emerson online ups from India. Keeping the focus on ever growing demands of customers, we are involved in providing Vertiv Line Interactive UPS System. Our product range is extensively used in various places. This Line Interactive UPS System is quality checked by our professionals on various quality stages before delivering to the clients. The offered products are reasonably priced. We specializes in designing Line Interactive UPS Systems, which is excellently designed and available to our clients at reasonable rates. Line Interactive ups are better than any standby ups as they provide faster response to a power failure. In this ups the separate battery charger, inverter and source selection switch have all been replaced by a combination inverter which makes it more efficient and reliable. The raw material used is of very high quality and all the modern techniques are utilized in the manufacture of the product.
Costa Power Industries Pvt. Ltd. is ups suppliers in India , Emerson ups dealers in Mumbai chain of Vertiv ups manufacturers , ups dealers in mumbai of global distributors such as emerson industrial ups , Vertiv ups , Emerson single phase ups , Vertiv digital ups, liebert emerson ups, emerson ups distributors , emerson online ups, emerson modular ups, three phase ups, emerson online ups, emerson industrial online ups, emerson offline ups etc. Costa power provides ups battery backup system with customized solutions and ups preventive maintenance, ups amc services nationwide with a strong presence in the thane, Mumbai, Mumbai Suburbs, Maharashtra interior parts and in India.
A disruption in your critical power system becomes catastrophic if the DC Power doesn’t perform the way you expect it to. Costa Power leverages years of experience, along with decades of industrial UPS and ups battery performance data, to ensure total power system availability while providing the insight into asset health and operating trends required to effectively optimize infrastructure performance. Costa Power deep infrastructure expertise is amplified by our use of data and our cradle-to-grave services, giving our customers insight into technology and operating trends and the confidence to effectively manage risk, reduce costs, increase utilization and make better decisions.
Costa power design, build and service for Data centers, Communication networks, Commercial and industrial applications We support today with a portfolio of power, thermal and infrastructure management solutions by help of principal Company Vertiv. Costa Power offer unsurpassed global scale and broad expertise, built from our heritage as top Emerson industrial ups dealers in Mumbai and providing Emerson industrial ups distributors in India .
Costa believe in Innovation which enabling flexible and Fast deployment, turnkey project solutions and seamless service Intelligent systems for smart & holistic network Products, solutions, services and expertise for Emerson online ups in Mumbai , and PAN India level as Emerson industrial ups suppliers and Emerson industrial ups distributors in India.
Costa Power have not only Expertise from design but commissioning derived from experience Innovative solutions that reduce costs, and speed deployment World-class services that drive uptime and deliver insights into performance Product, system and integrated solutions for Emerson industrial ups dealers in Bangalore and Emerson industrial ups suppliers in Pune with the exposure of across Maharashtra and in India.
As Costa power knows the importance of ups suppliers in Mumbai and value addition to clients requirements we always offers our mass-customized, standard solutions offer with ideal combination of best value and rapid delivery
Costa Power Industries Pvt Ltd is a leading company in the field of UPS AMC, UPS AMC Vendors, Emerson ups repairs UPS AMC Contract in Mumbai & UPS AMC Services. We have a specialization in Emerson UPS AMC Services . We are dealing in all kind Emerson UPS AMC related operations like Buy, Sell, Rent & UPS AMC services as well. Costa Power is maintaining position in market since many Years. We have started from Mumbai, Maharashtra then we set up the second workplace and service across India. Our clients are extremely pleased with our services. The organization has a long encounter in Emerson UPS AMC. We are the one of the approved and well known traders of a variety of UPS, Battery pack, UPS on rent and UPC AMC as well. We are working since last decades and offering UPS on lease to all major IT organizations & companies.
Every component of your critical infrastructure is designed for reliability, performance, and efficiency. And it should be that way. But each of these components, regardless if it is a ups battery from your power system, an entire UPS system or a thermal management unit, is comprised of pieces that must be proactively serviced to ensure proper functionality. That is why we're here. To help you boost the ups battery system performance in your data center and avoid costly problems, by implementing a ups preventive maintenance program.
Costa power is the best solution and service provide like ups amc vendor in Mumbai or ups amc service in Mumbai and in thane with PAN India residential solution to protect in even the most extreme conditions Solutions customized to meet specific needs and budget of customer who are looking for Emerson ups in Mumbai for their requirements.
CAPACITY | Emerson ITA 6 kVA | Emerson ITA 10 kVA | Emerson ITA 20 kVA |
---|---|---|---|
Input Parameters | |||
Rectier Type | IGBT Rectifier | ||
Rated Voltage | 220/380Vac single-phase three-wire/ three-phase four wire | 380Vac, three-phase four wire | |
Input voltage range | Single-phase 120Vac-276Vac /Three-phase 228Vac-478Vac | Single-phase 120Vac-288Vac Three-phase 228Vac-478Vac | Three-phase 228Vac-478Vac |
Input Freq Range | 45 Hz - 55 Hz | 45 Hz - 65 Hz | 40 Hz - 70 Hz |
Input Power Factor | 0.95 for Three Phase / >=0.99 for single Phase | >0.99 at Full Load | |
SMF VRLA Battery | |||
Battery Type | Lead Acid Maintenance Free | ||
Charging Capability | 3 Hr of recharging of Standard Model | 6 Hr of recharging of Standard Model | Max Charging Power 4.5kW |
No of Battery | 16 Nos of Battery | 30 - 40 (Selected on Site) | |
Output Parameters | |||
Rated Power (kVA/kW) | 6kVA/6kW | 10kVA/10kW | 20kVA/20kW |
Rated Voltage | Single Phase 230/220 Vac | Three Phase 380/400/415 Vac and Single Phase 230/220 Vac | |
Voltage Precision | 3% | 1% | |
Frequency Precision | 0.25% | ||
Output Voltage THD | 3% for Linear Load and 5% for Non Linear Load |
2% for Linear Load and 5% for Non Linear Load |
|
Load Crest Factor | 3:1 Comply with IEC 62040-3 | ||
Step Load Performance | 100% | ||
Output Mode | Terminal Strip | ||
Overload Performance
(% of Rated Load) |
105%-125%; 1min | "105%-125%; 5 Mins, 125%-150%; 1Min | "105%-125%; 5 Mins, 125%-150%; 1Min |
System parameters and Standards | |||
System Efficiency @100% | Up to 91% | Up to 93% | Up to 94% |
Dimension (mm) | 430x625x85 | 435x640x85 | 435x750x130(3U |
Net Weight (kg) | 17.8 | 21.5 | 35 |
Output Ratings | |||
---|---|---|---|
Output Power | 6kVA/4.2kW | ||
Norminal Output Voltage | 230 AVC | ||
Output Voltage Regulation | +/-1% | ||
Output Voltage Distortion
-With 100% Non Linear Load |
3% | ||
Output Frequency Tolerance
Phase locked with Mains |
3% | ||
Norminal Output Frequency | 50 Hz | ||
Overload at 0.7 pf Load is
transferred to Bypass after pre-determined time |
150% for 5 seconds | ||
Input Ratings | |||
Norminal Input Power | 230 AVC | ||
Permissible Input Voltage
Variation at Full Load |
165 - 275 VAC | ||
Norminal Input Frequency | 50 Hz | ||
Permissible Input Frequency Variation | 45 Hz to 55 Hz | ||
Battery Details | |||
Norminal DC Bus Voltage | 192 VDC | ||
Number of Blocks of SMF
Batteries |
76 blocks of 12 v each | ||
Types of Batteries Supported | Sealed Maintenance (SMF) 165-275 VAC | ||
Recharge Time upto
100% Capacity |
12 hours | ||
Backup | 4 hours | ||
Physical Parameters | |||
Width X Depth X Height | 425x730x550 mm | ||
Weight | 95 kg | ||
Color | MoonLight Grey-Blue Structured |
Nominal Rating [kVA] | 80 | 120 | 160 | 200 | 250 | 300 | 400 |
---|---|---|---|---|---|---|---|
(0.8 pf)/kW | 64kW | 96kW | 128kW | 160kW | 200kW | 240kW | 320kW |
Rectifier Type | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p |
Environment | |||||||
Noise | 63dBA | 63dBA | 65dBA | 68dBA | 70dBA | 71dBA | 72dBA |
Temperature | Operating Temperature : 0 to 400C** ; Storage Temperature : -20 to 700C | ||||||
Humidity | 0 up to 95%, non-condensing. | ||||||
Altitude | up to 1000 m above mean sea level (MSL) without de-rating | ||||||
Physical Characteristics | |||||||
Depth [mm] | 875 | ||||||
Width [mm] | 900 | 1300 | 1250 | 1890 | 1250 | 1890 | 1250 | 1890 | 1400 | 2060 | 1640 | 2280 | 2460 | 2460 | ||||||
Height [mm] | 1900 | ||||||
Weight [kgs] | 750 | 1120 | 1000 | 1475 | 1200 | 1725 | 1350 | 2000 | 1650 | 2150 | 1850 | 2540 | 2400 | 3100 | ||||||
Ingress Protection Class | Degree of Protection : IP 20 ( IP : 31 On Request ) | ||||||
Color | RAL 7021 | ||||||
Input | |||||||
Voltage | 380/400/415V (+15/-15%) -3Ph - 3w | ||||||
Frequency | 50 or 60 Hz +/-10% | ||||||
I/P THDi Up to | 3% * | ||||||
Power Factor | Up to 0.99 * | ||||||
Bypass | |||||||
Voltage | 380/400/415V (+10/-10%) -3Ph – 4w | ||||||
Frequency | 50 or 60 Hz +/-5% | ||||||
Output | |||||||
Voltage | 380/400/415V - 3Ph - 4w | ||||||
Voltage Stability | |||||||
- Steady State | +/-1% | ||||||
- 100% Load Step | +/- 5% | ||||||
Power Factor | 0.8 lag to 0.9 lead w/o De-ration | ||||||
Frequency | 50 or 60Hz | ||||||
Frequency Stability | |||||||
- Synchronised with the bypass supplier | +/- 1 % | ||||||
- Auto-Synchronised | +/- 0.1% |
Model | Emerson 10KVA UPS | Emerson 20KVA UPS | |
---|---|---|---|
Rating | Emerson 10kVA UPS (3in - 1out) | Emerson 20kVA UPS (3in - 1out) | |
Input | Rated voltage | 400vac 3-phase,4 wire | 400Vac 3-Phase,4 wire |
Volatge Range | 176 -288VAC at 100% load; 100VAC - 288VAC at 50% load | ||
Rated Frequency | 50Hz/60Hz | ||
Frequency Range | 40Hz ~ 70Hz | ||
Power factor | ≥0.95 at full load | ||
Input phase reversal correction | Yes | No | |
Output | Rated power | 10KVA/10kW | 20KVA/20kW |
Voltage | 220/230/240VAC (single phase) | ||
Frequency synchronization range | Rated frequency±3Hz. Configurable range: ±0.5Hz ~ ±5Hz | ||
Rated Power Factor | Unity | ||
Crest Factor | 3 : 1 | ||
Voltage harmonic distortion | 2% (linear load) | ||
Voltage Regulation | 2% | ||
Dynamic response recovery time | 60ms | 40ms | |
Isolation transformer | Inbuilt at ups output | ||
Inverter Overload Capability the utility mode | At 25°C: 105% ~ 125%- 5min; 125% ~ 150%-1min; 150%- more than 200ms | ||
Inverter Overload Capability the battery mode | At 25°C :105% ~125%-60~ 30 s; >125%- more than 200ms | ||
Efficiency | ECO Mode | > 94% | > 94% |
Online mode (AC-AC) | > 91% | > 91% | |
Inverter Efficiency(DC-AC) | 88% | 88% | |
Battery | Type | Sealed, lead-acid,Tubular,LI-ION | |
No's of Batteries | 12(1), 16, 20; 16 by default | 24(1), 32, 40; 32 by default | |
Battery Fuse disconnector | Inbuilt | ||
Battery charging capacity | 8A | 13A |
Model | Emerson GXT-MT 1 kVA | Emerson GXT-MT 2 kVA | Emerson GXT-MT 3 kVA |
---|---|---|---|
OUTPUT PARAMETERS | |||
Capacity | 1kVA / 800W | 2kVA / 1600W | 3kVA / 2400W |
Power Factor | 0.8 | ||
Nominal Voltage | 220 / 230 / 240 Vac | ||
Voltage THD | 3% - Linear Load =6% - Non Linear load | 4% - Linear Load =7% - Non Linear load | 4% - Linear Load 7% - Non Linear load |
Frequency Regulation - Free Run
(Unsynchronised with bypass) |
+ / - 0.5 Hz | ||
Frequency Regulation (Synchronised with bypass) | 47.5 - 52.5 HZ / 57.5 - 62.5 HZ | ||
Creast Factor | 3:1 max. | ||
AC - AC Efficiency | 88% R-Load, 87% RCD - Load | ||
Transfer time - Mains to battery | 0 millisec | ||
Transfer time - Inverter to bypass -
Synchronisation mode |
4 msec | ||
INPUT PARAMETERS | |||
Configuration | 1 phase, L-N + PE | ||
Nominal Voltage | 230 Vac | ||
Voltage range | 160V to 300V at 100% Load, At 60% Load 110V to 300 Vac | ||
Frequency | 50 / 60 Hz | ||
Frequency range - Hz | 40 - 70 Hz | ||
Power Factor | >=0.95 | ||
BATTERY PARAMETERS | |||
Type | SMF Battery | ||
No. of battery blocks (SB Model) | 3 X 7 Ah 6 X 7 Ah 6 X 9 Ah | ||
Battery Voltage (LB Model) | 36 VDC (3 Battery Blocks) | 96 VDC (8 Battery Blocks) | 96VDC (8 Battery Blocks) |
MODEL | Liebert GXT RT+ 1 kVA | Liebert GXT RT+ 2 kVA | Liebert GXT RT+ 3 kVA | ||
---|---|---|---|---|---|
Phase | 1 phase in / 1 phase out | ||||
CAPACITY | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | ||
INPUT | |||||
Nominal Voltage | 230 Vac | ||||
Voltage Range | Low Line Loss | 110 VAC ± 3% at 50% Load
176 VAC ± 3% at 100% Load |
|||
Low Line Comeback | 120 VAC ± 3% at 50% Load 186 VAC ± 3% at 100% Load | ||||
High Line Loss | 280 VAC ± 3% | ||||
High Line Comeback | 270 VAC ± 3% | ||||
Frequency Range | 40 Hz ~ 70 Hz | ||||
Power Factor | ≥ 0.99 @ 100% load | ||||
OUTPUT | |||||
Nominal Voltage | 208/220/230/240VAC | ||||
AC Voltage Regulation | ± 1% | ||||
Frequency Range (Synchronized Range) | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 (max.) | ||||
Harmonic Distortion | ≤ 3 % THD (Linear Load), ≤ 6 % THD (Non-linear Load) | ||||
Transfer Time | Bypass to Inverter (Line mode) | Zero | |||
Inverter to Bypass (Line mode) | 4 ms (Typical) | ||||
Waveform (Batt. Mode) | Pure Sinewave | ||||
EFFICIENCY on AC to AC mode@ 100% load. | 86% | 88% | 88% | ||
Inbuilt Isolation Transformer | No |
TECHNICAL SPECIFICATIONS | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ups Rating (kVA) | 100 | 120 | 160 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 |
Output active power at 35 °C*(kW) | 100 | 120 | 160 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 |
Output active power at 40 °C (kW) | 90 | 108 | 144 | 180 | 270 | 360 | 450 | 540 | 720 | 900 | 1080 |
INPUT | |||||||||||
Nominal mains input voltage / voltage range* (V) | 400 (200 to 460), 3Ph or 3Ph + N | ||||||||||
Nominal bypass input voltage / voltage range* (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | ||||||||||
Nominal frequency / frequency tolerance (Hz) | 50±10%(60 selectable) | ||||||||||
Input Power Factor | ≥ 0.99 | ||||||||||
Input current distortion (THDi) (%) | ≤3 | ||||||||||
OUTPUT | |||||||||||
Nominal output voltage (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | ||||||||||
Nominal output frequency (Hz) | 50 (60 selectable) | ||||||||||
Output voltage stability by load variation 0-100% (%) | ±1 Complies with IEC/EN 62040-3, Class 1 | ||||||||||
Output frequency stability | ±2 (2, 3, 4, 5 selectable) | ||||||||||
Inverter Overload Capacity* | 110% continuous, 125% for 10mins, 150% for 1min | ||||||||||
Short circuit current for 200 ms | 2.2 In | ||||||||||
Load crest factor handled without derating the ups (Ipk/Irms) | 3:1 | ||||||||||
Compatibility with loads | Any power factor (leading or lagging) up to 1 | ||||||||||
DIMENSION AND WEIGHT | |||||||||||
Height (mm) | 1950 | ||||||||||
Width (mm) | 500 | 750 | 1000 | 1250 | 1600 | 2000 | 2650 | ||||
Depth (mm) | 900 | ||||||||||
Net Weight (kg) | 370 | 510 | 725 | 990 | 1135 | 1550 | 2275 |
Nominal Ratings(kVA/kW) | 80kVA/kW | 100kVA/kW | 120kVA/kW | 160kVA/kW | 200kVA/kW | |
---|---|---|---|---|---|---|
Input | ||||||
Nominal input voltage(V) | 380/400/415 | |||||
Input voltage range without battery discharge (V) | 229~478 | |||||
Nominal input frequency(Hz) | 50/60 | |||||
Input frequency range(Hz) | 40-70 | |||||
Bypass voltage tolerance(%) | Upper limit: +10%, +15%, or +20% default: +15%;
Lower limit: -10%, -20%, -30% or -40% default: -20% |
|||||
Bypass frequency tolerance(%) | +/- 10% or +/- 20%, default: +/-10% | |||||
Input power factor(kW/kVA) | 0.99 | |||||
Current THD at full linear load(THDi%) | 3% | |||||
Output | ||||||
Nominal output voltage (V) | 380/400/415 | |||||
Nominal output frequency (Hz) | 50/60 | |||||
Nominal active power (kW) | PF=1 | |||||
THDv with 100% linear load (%) | 1% | |||||
Inverter overload capacity | 110% for 60 min; 125% 10min; 150% for 1 min | |||||
Dimensions and weight | ||||||
Dimensions (W x D x H) mm | 600 x 1000 x 2000 | |||||
Weight(Net weight) | 385 430 430 475 520 |
Rated Power (In kVA/kW)* | 18 | 36 | 54 | 72 | 90 | |
---|---|---|---|---|---|---|
Input | ||||||
Rated input voltage | 380/400/415Vac, 3-phase and 4 -wire | |||||
Input voltage range | 305~477V ; 304-228 V for ( o/p derated below 80%) | |||||
Rated operating frequency | 50/60Hz | |||||
Input frequency range | 40-70Hz | |||||
Input power factor | =0.99 at full load, >0.98 at half load | |||||
THDi* | Linear full load 3% (battery float charge); Non-liner full load 5% (battery float charge) | |||||
Input power walk-in duration | 20s | |||||
Output | ||||||
Inverter output voltage | 380/400/415Vac, 3-phase and 4-wire | |||||
Nominal output frequency | 50/60 (settable) | |||||
Inverter overload capacity | 1 hour for 110%; 10 mins for 125%; 1 min for 150%; 200ms for >150% | |||||
Voltage Stability | ±1% (balanced) | |||||
Total harmonic voltage distortion | 2% (linear load); 4% (non-linear load) | |||||
Slew rate | 0.6Hz/sec | |||||
Dimensions and weight | ||||||
Dimensions (W x D x H) (mm) | 600 x 1100 x 2000 | |||||
Weight(kg) | 228 256 284 321 340 |
MODEL | SPECIFICATION | EXi 600 VA | LXi 600 VA | CX 600 VA | 1000 VA LB |
---|---|---|---|---|---|
CAPACITY | VA/W | 600 VA/360 Watt. | 600 VA/360 Watt. | 600 VA/360 Watt. | 1000 VA/600 Watt. |
Input | Voltage | 220/230 VAC | |||
Voltage Range | 140-300 VAC | ||||
Frequency Range | 50 Hz | ||||
OUTPUT | AC Voltage Regulation (Batt. Mode) | ±10% | |||
Frequency Range (Batt. Mode) | 50 Hz ±1 Hz | ||||
Transfer Time | Typical 2-6 ms | ||||
Waveform (Batt. Mode) | Simulated Sine Wave | ||||
Overload | 110% +/-10% Shutdown after 5 mins | ||||
BATTERY | Battery Type & Number | 12 V/9Ah x 1 | 12 V/7 Ah x 2 | 12 V/7 Ah x 1 | 12VDC |
Floating Charge Voltage | 13.7 VDC ± 2% | ||||
Overcharge Protection | 14.5VDC ± 2% | ||||
Maximum Charge Current | 20 A | ||||
Typical Recharge Time | 6-8 hours up to 90% capacity | ||||
TRANSFER TIME | Minimum line break for transfer to battery | Typical 4-8 msec | |||
PHYSICAL | Dimension, D X W X H (mm) | 282 x 101 x 142 | 353 X 150 x 162 | 279 X 101 X142 | 350 x 146 x 160 |